mk3:stowiring
Dies ist eine alte Version des Dokuments!
Relay Wiring – ReadBack Relays with STO
Only for GRNBM_MK3_HV_STO
Wiring Diagram
This diagram shows how to wire the relays with state feedback using 4 SPDT contacts per side (positive and negative). Feedback is routed through RB1–RB8 lines, each color-coded for clarity. The relays directly switch battery plus and minus without any precharge stage.
Safety Notes
Relay coils must operate at 12 V.
Recommended relay type: C320K/1000
Only handle feedback wiring with HV disconnected!
Check wiring regularly for secure connections.
STO Output (not shown in diagram)
A separate 24 V STO output is available for controlling inverters or similar devices.
Refer to your inverter’s documentation for proper connection details.
mk3/stowiring.1747991195.txt.gz · Zuletzt geändert: 2025/05/23 09:06 von grnbms_tech