Request your own Battery Profile

Here you can request a new battery profile for your GRNbms device.

⚠️ Important Rules:

  • Only one active request allowed at a time.
  • Request is linked to your user account and cannot be moved.
  • Your device must be registered to the same account.

Field-by-Field Explanation:

Basics

  • Name: Choose a clear name for your battery.

➡️ Ideally include manufacturer, model/type, and other important details
(e.g., „LG INR18650-MJ1 3500mAh“).
This helps with faster and more accurate matching during approval.
—-

Cell Voltages

  • Min Volt Warning: Below this voltage per cell you get a warning.
  • Min Volt Error: Below this voltage per cell the system enters error.
  • Max Volt Warning: Above this voltage per cell you get a warning.
  • Max Volt Error: Above this voltage per cell the system enters error.

¹ Attention:

These voltages are per cell!
Internally, the system multiplies by the number of cells in series (12S = ×12).


Temperature

  • Temp Sensor Type: Choose the sensor used (e.g., NTC10k, PT1000, etc.).
  • Temp Sensor Count (GRN CMU): How many temp sensors your CMU uses (0–3).

ℹ️ Note:
These fields are only relevant if you are using a GRN CMU (Cell Monitoring Unit).
If your battery does not use a GRN CMU, you can ignore these settings.

  • Min Temp Warning: Below this temperature you get a warning.
  • Min Temp Error: Below this, the system enters error.
  • Max Temp Warning: Above this temperature you get a warning.
  • Max Temp Error: Above this, the system enters error. (All values in °C)

—-

Balancing

  • Min Balance Voltage: Start balancing when cell voltage reaches this value.
  • Max Balance Voltage: Stop balancing above this value.
  • Max Balance Load: Maximum battery load (in %) up to which balancing is still active.
    If the load exceeds this percentage, balancing is automatically paused to avoid interfering with heavy charging/discharging.
  • Balance Current: Estimated balancing current per cell (A).
  • Balance Target (overall): Balancing goal voltage across all cells.

—-

Delta (Cell differences)

  • Delta Warning 0 Load: Maximum allowed voltage difference between cells at no load (relaxed battery).
  • Delta Error 0 Load: Error if exceeded at no load.
  • Delta Warning Full Load: Max allowed difference under full load.
  • Delta Error Full Load: Error if exceeded under full load.

¹ Attention:

The value you set is per cell but the system multiplies it with the number of cells in series for calculations.


Current Limits

  • Max DC Current: Max discharge current allowed per cell (in Ampere).
  • Max CH Current: Max charge current allowed per cell (in Ampere).
  • Cell Capacity Wh: Energy content of one single cell in Watt-hours.

² Attention (for currents):

DC and CH currents are multiplied by parallel strings.
⚡ Example:
If you have 5P (5 cells in parallel), the allowed system current = Value × 5.

BUT:
If you use pre-assembled battery modules (e.g., 12S5P module), the whole module counts as 1 parallel group for the BMS!
→ So in this case, do NOT multiply by 5 manually!

³ Attention (for capacity):
The „Cell Capacity Wh“ must be for ONE cell only.
The BMS calculates total pack energy internally:
Capacity × Number of all cells (series × parallel).

⚡ Example:

  • Module = 12S5P
  • Total cells = 12 × 5 = 60
  • If total module has 600Wh,

then cell capacity must be:
600Wh ÷ 12 cells = 50Wh
(not ÷60!)


Tables (Temperature / SOC Maps)

  • Temperature vs Current: Defines how much current is allowed depending on cell temperature.🔥 The colder or hotter it gets, the lower the allowed charge/discharge current.
  • SOC vs Current: Defines how much current is allowed depending on State of Charge (SOC %).🔋 At very low or very high SOC, the allowed current is automatically reduced.

Important: Both maps limit the maximum available current in % relative to the normal current settings!

(Example: If 50% is set, only half the current is allowed at that point.)

Voltage vs SOC:

  • Defines how a measured cell voltage is mapped to a SOC %.

What you must absolutely watch out for:

✅ Always enter per cell values unless otherwise stated.
✅ Always think about series cells for voltages.
✅ Always think about parallel groups (modules) for currents.
✅ For capacity, use only per-cell capacity, independent of parallel count.


Ready?

After filling everything carefully, press „Send Request“.
Your request will be reviewed manually.

What happens after submission?

After you send the request, it will go through a manual review by our team.

You will receive an email notification at every step:

When you submit the request

When your request is approved

When your request is rejected