Here you can request a new battery profile for your GRNbms device.
⚠️ Important Rules:
- Only one active request allowed at a time.
- Request is linked to your user account and cannot be moved.
- Your device must be registered to the same account.
Field-by-Field Explanation:
Basics
- Name: Choose a clear name for your battery.
➡️ Ideally include manufacturer, model/type, and other important details (e.g., „LG INR18650-MJ1 3500mAh“). —-
This helps with faster and more accurate matching during approval.
Cell Voltages
- Min Volt Warning: Below this voltage per cell you get a warning.
- Min Volt Error: Below this voltage per cell the system enters error.
- Max Volt Warning: Above this voltage per cell you get a warning.
- Max Volt Error: Above this voltage per cell the system enters error.
❗ ¹ Attention:
These voltages are per cell!
Internally, the system multiplies by the number of cells in series (12S = ×12).
Temperature
- Temp Sensor Type: Choose the sensor used (e.g., NTC10k, PT1000, etc.).
- Temp Sensor Count (GRN CMU): How many temp sensors your CMU uses (0–3).
ℹ️ Note:
These fields are only relevant if you are using a GRN CMU (Cell Monitoring Unit).
If your battery does not use a GRN CMU, you can ignore these settings.
- Min Temp Warning: Below this temperature you get a warning.
- Min Temp Error: Below this, the system enters error.
- Max Temp Warning: Above this temperature you get a warning.
- Max Temp Error: Above this, the system enters error. (All values in °C)
—-
Balancing
- Min Balance Voltage: Start balancing when cell voltage reaches this value.
- Max Balance Voltage: Stop balancing above this value.
- Max Balance Load: Maximum battery load (in %) up to which balancing is still active.
If the load exceeds this percentage, balancing is automatically paused to avoid interfering with heavy charging/discharging. - Balance Current: Estimated balancing current per cell (A).
- Balance Target (overall): Balancing goal voltage across all cells.
—-
Delta (Cell differences)
- Delta Warning 0 Load: Maximum allowed voltage difference between cells at no load (relaxed battery).
- Delta Error 0 Load: Error if exceeded at no load.
- Delta Warning Full Load: Max allowed difference under full load.
- Delta Error Full Load: Error if exceeded under full load.
❗ ¹ Attention:
The value you set is per cell but the system multiplies it with the number of cells in series for calculations.
Current Limits
- Max DC Current: Max discharge current allowed per cell (in Ampere).
- Max CH Current: Max charge current allowed per cell (in Ampere).
- Cell Capacity Wh: Energy content of one single cell in Watt-hours.
❗ ² Attention (for currents):
DC and CH currents are multiplied by parallel strings.
⚡ Example:
If you have 5P (5 cells in parallel), the allowed system current = Value × 5.
BUT:
If you use pre-assembled battery modules (e.g., 12S5P module), the whole module counts as 1 parallel group for the BMS!
→ So in this case, do NOT multiply by 5 manually!
❗ ³ Attention (for capacity):
The „Cell Capacity Wh“ must be for ONE cell only.
The BMS calculates total pack energy internally:
Capacity × Number of all cells (series × parallel).
⚡ Example:
- Module = 12S5P
- Total cells = 12 × 5 = 60
- If total module has 600Wh,
then cell capacity must be:
600Wh ÷ 12 cells = 50Wh
(not ÷60!)
Tables (Temperature / SOC Maps)
- Temperature vs Current: Defines how much current is allowed depending on cell temperature.🔥 The colder or hotter it gets, the lower the allowed charge/discharge current.
- SOC vs Current: Defines how much current is allowed depending on State of Charge (SOC %).🔋 At very low or very high SOC, the allowed current is automatically reduced.
❗ Important: Both maps limit the maximum available current in % relative to the normal current settings!
(Example: If 50% is set, only half the current is allowed at that point.)
Voltage vs SOC:
- Defines how a measured cell voltage is mapped to a SOC %.
What you must absolutely watch out for:
✅ Always enter per cell values unless otherwise stated.
✅ Always think about series cells for voltages.
✅ Always think about parallel groups (modules) for currents.
✅ For capacity, use only per-cell capacity, independent of parallel count.
Ready?
After filling everything carefully, press „Send Request“.
Your request will be reviewed manually.