1. Power Supply

The GRNbms MK3 supports both High Voltage (HV) and Low Voltage (LV) operation.

➤ Low Voltage Mode (12 V System)

  • Connect 12 V to the „Jump Start“ connector
  • This powers the BMS directly for low-voltage applications or setup/configuration

➤ High Voltage Mode

  • For high-voltage setups, connect the BMS using the dedicated HV connectors

HV POS Connector:

  • B+ → Connect directly to Battery Positive
  • O+ → Output (post-relay) – not required for power supply

HV NEG Connector:

  • B- → Connect directly to Battery Negative
  • O- → Output (post-relay) – not required for power supply

✅ To power the BMS: only B+ and B- are needed

⚠️ Valid voltage range: 150 V – 1200 V DC Operating the BMS outside this range may cause malfunction or damage.

Additionally, for safety and EMI compliance:

  • Connect the battery chassis to the E pin on the CHASSIS connector
  • Use a dual connection if possible for redundancy

👉 Details about relay and output wiring can be found here

2. Network Connection

An internet connection is required for the initial setup and activation of your BMS.

📝 Note: A GRNbms.de account is required to complete the setup.
You can create one during the initial configuration or in advance here.

  • Connect the BMS (ETHERNET 1 Connector) to your local network using a standard RJ45 Ethernet cable
  • The BMS will automatically obtain an IP address via DHCP (from your router)

➤ Accessing the BMS

Once connected, try opening one of the following in your browser:

💡 These names work only if your router supports mDNS or local hostname resolution.

➤ Can’t find your BMS?

No problem – just visit grnbms.de
There you can see all BMS devices in your local network.