Benutzer-Werkzeuge

Webseiten-Werkzeuge


mk3:quick_start_guide

Dies ist eine alte Version des Dokuments!


1. Power Supply

The GRNbms MK3 supports both High Voltage (HV) and Low Voltage (LV) operation.

➤ Low Voltage Mode (12 V System)

  • Connect 12 V to the „Jump Start“ connector
  • This powers the BMS directly for low-voltage applications or setup/configuration

➤ High Voltage Mode

  • For high-voltage setups, connect the BMS using the dedicated HV connectors

HV POS Connector:

  • B+ → Connect directly to Battery Positive
  • O+ → Output (post-relay) – not required for power supply

HV NEG Connector:

  • B- → Connect directly to Battery Negative
  • O- → Output (post-relay) – not required for power supply

✅ To power the BMS: only B+ and B- are needed

⚠️ Valid voltage range: 150 V – 1200 V DC Operating the BMS outside this range may cause malfunction or damage.

Additionally, for safety and EMI compliance:

  • Connect the battery chassis to the E pin on the CHASSIS connector
  • Use a dual connection if possible for redundancy

👉 Details about relay and output wiring can be found here

Schritt 2

mk3/quick_start_guide.1744037107.txt.gz · Zuletzt geändert: 2025/04/07 14:45 von grnbms_tech