  1. Firmware

Check if the BMS and all connected devices have the latest firmware installed.

  
To do this, click on **Updates -> Check updates**.  
If new updates are available, update all devices to the latest version.  
  1. Canbus

It is a prerequisite that the CAN bus is properly terminated!

Disconnect the BMS from the power supply and use a multimeter to measure the resistance between CAN High and CAN 
Low at the respective CAN port where something is connected. The resistance must be 120 Ohms.  
If you measure a different value, adjust the termination resistor using the red jumper on the BMS board and 
repeat the measurement.  