basic_conditions
Unterschiede
Hier werden die Unterschiede zwischen zwei Versionen angezeigt.
| Nächste Überarbeitung | Vorhergehende Überarbeitung | ||
| basic_conditions [2025/01/12 11:12] – angelegt grnbms | basic_conditions [2025/01/12 21:07] (aktuell) – grnbms | ||
|---|---|---|---|
| Zeile 1: | Zeile 1: | ||
| - | 1. Check if the BMS and all connected devices have the latest firmware installed. | + | |
| - | To do this, click on **Updates | + | |
| - | If new updates are available, update all devices to the latest version. | + | **1. Firmware** |
| + | |||
| + | Check if the BMS and all connected devices have the latest firmware installed.To do this, click on Updates | ||
| + | |||
| + | **2. Canbus** | ||
| + | |||
| + | It is a prerequisite that the CAN bus is properly terminated! Disconnect the BMS from the power supply and use a multimeter to measure the resistance between CAN High and CAN Low at the respective CAN port where something is connected. The resistance must be 120 Ohms. If you measure a different value, adjust the termination resistor using the red jumper on the BMS board and repeat the measurement. | ||
| + | |||
| + | '' | ||
basic_conditions.1736680329.txt.gz · Zuletzt geändert: 2025/01/12 11:12 von grnbms