===== GRNbms MK3 Mini – Wiring & Pinout ===== This page provides an overview of the wiring and pinout for the **GRNcmu 18s**. Please refer to the respective Wiki pages for detailed information about [[:mk3:canbus|CAN]] communication. ==== Power Supply ==== * **Recommended input voltage:** 11 – 14 V DC * Power should be supplied via the designated power outputs of the GRNbms. ==== GRNcmu Connection ==== {{:mk3:cmu18spinout.png?nolink&600}} ^Connector 1^ | |1|GND Temp Sensor| |2|GND Temp Sensor| |3|Temp Sensor 3| |4|Cell 17| |5|Cell 15| |6|Cell 13| |7|Cell 11| |8|Cell 9| |9|Cell 7| |10|Cell 5| |11|Cell 3| |12|Cell 1| |13|Temp Sensor 2| |14|Temp Sensor 1| |15|Cell 18| |16|Cell 16| |17|Cell 14| |18|Cell 12| |19|Cell 10| |20|Cell 8| |21|Cell 6| |22|Cell 4| |23|Cell 2| |24|Cell 0| ^Connector 2 + 3^ | |1|12V Supply| |2|CAN-High| |3|Rail Positiv| |4|NOT CONNECT!| |5|GND| |6|CAN-Low| |7|Rail Negativ| |8|NOT CONNECT!| The positive and negative rails must each be connected to EVERY CMU in the system. Connectors 2 and 3 are internally connected and can therefore be used for day chaining.