Benutzer-Werkzeuge

Webseiten-Werkzeuge


supported_cmu_s

Unterschiede

Hier werden die Unterschiede zwischen zwei Versionen angezeigt.

Link zu dieser Vergleichsansicht

Beide Seiten der vorigen RevisionVorhergehende Überarbeitung
Nächste Überarbeitung
Vorhergehende Überarbeitung
supported_cmu_s [2025/04/27 14:31] – [GRNcmu] grnbmssupported_cmu_s [2025/04/27 14:39] (aktuell) – [GRNcmu] grnbms
Zeile 3: Zeile 3:
 ==== GRNcmu ==== ==== GRNcmu ====
  
-  * GRNcmu passive (all variants) - 33 Cmus @ 1 Can Port / 1 GRNcmu handle up to 4 modules +  * GRNcmu passive (all variants) - 33 CMU'@ 1 Can Port / 1 GRNcmu handle up to 4 modules 
-  * GRNcmu 18S active - 33 Cmus @ 1 Can Port / 1 GRNcmu handle 1 module+  * GRNcmu 18S active - 33 CMU'@ 1 Can Port / 1 GRNcmu handle 1 module
  
-  - **GRNcmu's have the original OEM board connector, and can re-use OEM celltab cables** +  - GRNcmu's have the original **OEM board connector**, and can **re-use OEM celltab cables** 
-  - **GRNcmu's passive are autosensing for 8S or 12S variant MEB battery modules** +  - GRNcmu's passive are **autosensing for 8S or 12S variant MEB battery modules** 
-  - **GRNcmu's have a limit of 33 unique can-id's per GRNbms can- port**+  - GRNcmu's have a limit of** 33 unique can-id's**  per GRNbms can- port
  
  
 ==== MEB OEM CMU ==== ==== MEB OEM CMU ====
  
-The MEB OEM CMU's have all the same partnumber, but have firmware flashed onto them that defines working for 12S 156Ahr Meb battery modules or 8S 234Ahr MEB battery modules.\\+The MEB OEM CMU's have all the same partnumber, but have firmware flashed onto them that defines working for 12S 156Ahr MEB battery modules or 8S 234Ahr MEB battery modules.\\
 Make sure you can tell from what type of donor car you get the OEMcmu's/battery modules, one cannot see the difference from the outside/or partnumber!!! Mixing will create errors or worse. Make sure you can tell from what type of donor car you get the OEMcmu's/battery modules, one cannot see the difference from the outside/or partnumber!!! Mixing will create errors or worse.
  
-  * MEB OEM 8S 4port CMU (all ports mandatory connected to MEB 8S battery modules)  \\ MAX number MEB OEM CMU connected = 3x 8S CMU's @ 1 GRNbms can-port.  \\ additional unlocked GRNbms can-ports can create larger battery packs. \\ Largest battery system possible with MEB OEM 8S 4portCMU's = 36 8S MEB battery,limiting factor may be the inverter of choice+  * MEB OEM 8S 4port CMU (all ports mandatory connected to MEB 8S battery modules) \\ MAX number MEB OEM CMU connected = 3x 8S CMU's @ 1 GRNbms can-port. \\ additional unlocked GRNbms can-ports can create larger battery packs. \\ Largest battery system possible with MEB OEM 8S 4portCMU's = 36 8S MEB battery,limiting factor may be the inverter of choice 
 + 
 +  * MEB OEM 12S 4port CMU (all ports mandatory connected to MEB 12S battery modules) \\ MAX number MEB OEM CMU connected = 2x 12S 4-port CMU's @ 1 GRNbms can-port. \\ additional unlocked GRNbms can-ports can create larger battery packs. \\ Largest battery system possible with MEB OEM 12S 4portCMU's = 24 12S MEB battery,limiting factor may be the inverter of choice 
  
-  * MEB OEM 12S 4port CMU (all ports mandatory connected to MEB 12S battery modules)  \\ MAX number MEB OEM CMU connected = 2x 12S 4-port CMU's @ 1 GRNbms can-port.  \\ additional unlocked GRNbms can-ports can create larger battery packs. \\ Largest battery system possible with MEB OEM 12S 4portCMU's = 24 12S MEB battery,limiting factor may be the inverter of choice  
supported_cmu_s.1745764310.txt.gz · Zuletzt geändert: 2025/04/27 14:31 von grnbms