 ==== Basic Wiring Rules ==== ==== Basic Wiring Rules ====
  
-  * +  * CAN uses **two lines**: ''HIGH''  (CAN-H) and ''LOW''  (CAN-L) 
- +  * All devices are connected in **parallel**  along one continuous **bus line** 
-CAN uses **two lines**: ''HIGH''  (CAN-H) and ''LOW''  (CAN-L) +  * No star topology or long branches – only short drop lines (max. **500 mm**) to each device
- +
-  * +
- +
-All devices are connected in **parallel**  along one continuous **bus line** +
-  * +
- +
-No star topology or long branches – only short drop lines (max. **500 mm**) to each device+
  
 ==== Termination Resistors ==== ==== Termination Resistors ====
  
-  * +  * A **120 Ω resistor**  must be placed at **each end**  of the bus 
- +  * The BMS and last CMU typically provide termination if configured correctly 
-A **120 Ω resistor**  must be placed at **each end**  of the bus +  * Only **two resistors total**  on the bus – no more, no less
- +
-  * +
- +
-The BMS and last CMU typically provide termination if configured correctly +
- +
-  * +
- +
-Only **two resistors total**  on the bus – no more, no less+
  
 ''⚠️ Missing or incorrect termination leads to unstable or no communication'' ''⚠️ Missing or incorrect termination leads to unstable or no communication''
Zeile 36: Zeile 21:
 ==== Example Devices on the Bus ==== ==== Example Devices on the Bus ====
  
-  * +  * **BMS:**  Master device 
- +  * **CMUs:**  Cell Management Units – multiple allowed 
-**BMS:**  Master device +  * **Other extensions:**  e.g. displays, current sensors, inverter Each device has a **CAN HIGH / CAN LOW**  pair that must be connected to the main line.
-  * +
- +
-**CMUs:**  Cell Management Units – multiple allowed +
-  * +
- +
-**Other extensions:**  e.g. displays, current sensors, inverter +
-Each device has a **CAN HIGH / CAN LOW**  pair that must be connected to the main line. +
 ''🛠️ Make sure the **CAN baud rate and ID settings**  match across all devices on the bus \\ Check under **Connections → CAN Bus**  for configuration options'' ''🛠️ Make sure the **CAN baud rate and ID settings**  match across all devices on the bus \\ Check under **Connections → CAN Bus**  for configuration options''
  
  
mk3/wirringcan.1744051875.txt.gz · Zuletzt geändert: 2025/04/07 18:51 von grnbms_tech