-  * +  * When **"Power On"**  is pressed, the BMS automatically performs an **isolation test** 
- +  * If the test passes, the **precharge sequence**  starts, followed by activation of the positive and negative relays 
-When **"Power On"**  is pressed, the BMS automatically performs an **isolation test** +  * The system is now live and ready for operation
- +
-  * +
- +
-If the test passes, the **precharge sequence**  starts, followed by activation of the positive and negative relays +
- +
-  * +
- +
-The system is now live and ready for operation+
  
 === Low Voltage Systems === === Low Voltage Systems ===
  
-  * +  * Same flow as above, **but without isolation test** 
- +  * Relays are closed after a short delay and the inverter is powered up
-Same flow as above, **but without isolation test** +
- +
-  * +
- +
-Relays are closed after a short delay and the inverter is powered up+
  
 ---- ----
  
 ==== When System is Active ==== ==== When System is Active ====
 +
 +{{:mk3:screenshot2025-04-07202141.png?nolink&300}}
  
 Once relays are engaged, two buttons become visible: Once relays are engaged, two buttons become visible:
  
-  *+  * 🔴 **Emergency Stop**  Instantly disables all relays – use only in emergency situations ''⚠️ Cuts power without any shutdown process. May lead to system faults if used during operation.'' 
 +  * 🔵 **Shutdown**  Recommended method for turning the system off ''Sends a clean shutdown signal to the inverter and safely disconnects all relays afterward''
  
-🔴 **Emergency Stop** \\ Instantly disables all relays – use only in emergency situations ''⚠️ Cuts power without any shutdown process. May lead to system faults if used during operation.''+----
  
-  * 
- 
-🔵 **Shutdown** \\ Recommended method for turning the system off ''Sends a clean shutdown signal to the inverter and safely disconnects all relays afterward'' 
- 
----- 
  
 ==== Status Indicators ==== ==== Status Indicators ====
  
-  * +  * **State:**  Shows current switch/test state (e.g. ''Waiting'', ''Testing Isolation'', ''Ready'', ''Error''
- +  * **Relays:**  Displays relay status (e.g. ''Open'', ''Closed'', ''Precharge'', ''Error'') ''🔍 Always check both values before powering on or off the system manually.''
-**State:** \\ Shows current switch/test state (e.g. ''Waiting'', ''Testing Isolation'', ''Ready'', ''Error'') +
- +
-  * +
- +
-**Relays:** \\ Displays relay status (e.g. ''Open'', ''Closed'', ''Precharge'', ''Error'') ''🔍 Always check both values before powering on or off the system manually.''+
  
  