Benutzer-Werkzeuge

Webseiten-Werkzeuge


mk3:relaymode

Unterschiede

Hier werden die Unterschiede zwischen zwei Versionen angezeigt.

Link zu dieser Vergleichsansicht

Beide Seiten der vorigen RevisionVorhergehende Überarbeitung
Nächste Überarbeitung
Vorhergehende Überarbeitung
mk3:relaymode [2025/04/07 17:17] grnbms_techmk3:relaymode [2025/05/23 09:10] (aktuell) – [Available Relay Modes] grnbms_tech
Zeile 1: Zeile 1:
-===== Relay Type Configuration =====+===== Relay Mode Configuration =====
  
-To set the relay control mode, go to **Battery → Relay Type** in the sidebar.+To set the relay control mode, go to **Battery → Relay Mode** in the sidebar.
  
 This setting determines how the BMS handles relay logic based on your system voltage and wiring. This setting determines how the BMS handles relay logic based on your system voltage and wiring.
Zeile 11: Zeile 11:
    * Designed for **high voltage systems**    * Designed for **high voltage systems**
   * Activates the full 3-relay setup including precharge and isolation test   * Activates the full 3-relay setup including precharge and isolation test
-  * Matches the HV relay wiring described [[:mk3:here|]]+  * Matches the HV relay wiring described [[:mk3:hvrelaywirring|here]]
  
 **2. LV with Precharge** **2. LV with Precharge**
Zeile 17: Zeile 17:
   * For **low voltage systems**  (e.g. 12 V or 24 V setups)   * For **low voltage systems**  (e.g. 12 V or 24 V setups)
   * Uses a simplified relay logic with optional precharge   * Uses a simplified relay logic with optional precharge
 +  * Matches the HV relay wiring described [[:mk3:lvrelays|here]]
 +
 +**3. ReadBack Relays with STO** \\ //Only available on GRNbms_MK3_HV_STO//
 +
 +  * Monitors relay state of battery plus and minus via 4 SPDT switches per relay
 +  * Simple on/off switching without precharge
 +  * Full monitoring of switch-on and switch-off process
 +  * Includes a 24 V STO output to control external inverters
 +  * Wiring diagram available [[:mk3:stowiring|here]]
  
 ''⚠️ Make sure the selected mode matches your **physical wiring**, otherwise the system may not function correctly.'' ''⚠️ Make sure the selected mode matches your **physical wiring**, otherwise the system may not function correctly.''
 +
  
 ==== Activation Required ==== ==== Activation Required ====
mk3/relaymode.1744046226.txt.gz · Zuletzt geändert: 2025/04/07 17:17 von grnbms_tech