| Zeile 10: | Zeile 10: | ||
| ==== GRNcmu Connection ==== | ==== GRNcmu Connection ==== | ||
| - | {{: | + | {{: |
| + | |||
| + | ^Connector 1^ | | ||
| + | |1|GND Temp Sensor| | ||
| + | |2|GND Temp Sensor| | ||
| + | |3|Temp Sensor 3| | ||
| + | |4|Cell 17| | ||
| + | |5|Cell 15| | ||
| + | |6|Cell 13| | ||
| + | |7|Cell 11| | ||
| + | |8|Cell 9| | ||
| + | |9|Cell 7| | ||
| + | |10|Cell 5| | ||
| + | |11|Cell 3| | ||
| + | |12|Cell 1| | ||
| + | |13|Temp Sensor 2| | ||
| + | |14|Temp Sensor 1| | ||
| + | |15|Cell 18| | ||
| + | |16|Cell 16| | ||
| + | |17|Cell 14| | ||
| + | |18|Cell 12| | ||
| + | |19|Cell 10| | ||
| + | |20|Cell 8| | ||
| + | |21|Cell 6| | ||
| + | |22|Cell 4| | ||
| + | |23|Cell 2| | ||
| + | |24|Cell 0| | ||
| + | |||
| + | ^Connector 2 + 3^ | | ||
| + | |1|12V Supply| | ||
| + | |2|CAN-High| | ||
| + | |3|Rail Positiv| | ||
| + | |4|NOT CONNECT!| | ||
| + | |5|GND| | ||
| + | |6|CAN-Low| | ||
| + | |7|Rail Negativ| | ||
| + | |8|NOT CONNECT!| | ||
| + | |||
| + | The positive and negative rails must each be connected to EVERY CMU in the system. | ||
| + | |||
| + | Connectors 2 and 3 are internally connected and can therefore be used for day chaining. | ||
mk3/cmu18s.1762455529.txt.gz · Zuletzt geändert: 2025/11/06 18:58 von grnbms_tech